Air Quality Sensors
1,226 ResultsPart | Availability | Purchasing | RoHS/Lead | Type | Sensor Type | Measuring Range - Min | Measuring Range - Max | Accuracy | Output Type | Supply Voltage - Min | Supply Voltage - Max | Minimum Operating Temperature | Maximum Operating Temperature | Series |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr: PSD4-SMELL-200 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series SMELL Digital Solid Polymer Sensor 200ppm | 0In Stock | Solid Polymer | Smell | 0 PPM | 200 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | PSD4 Series | ||
Mfr: INIR5-BU1.8 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Digital Infrared Gas Sensor - Non-certified, optional ATEX/IECEx Ex ia - Butane (R600) 0-1.8% | 0In Stock | Integrated Infrared (INIR) | R600 | 0 % | 1.8 % | UART and Analog | INIR5 Series | |||||||
Mfr: PSD4-TVOC-10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series TVOC Digital Solid Polymer Sensor 10ppm | 0In Stock | Solid Polymer | TVOC | 0 PPM | 10 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | PSD4 Series | ||
Not Available Online | ||||||||||||||
Mfr: PSD4-PH3-2000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series Phosphine Digital Solid Polymer Sensor 2000ppm | 0In Stock | Solid Polymer | PH3 | 0 PPM | 2000 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | PSD4 Series | ||
Mfr: INIR5-ME10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Digital Infrared Gas Sensor - Non-certified, optional ATEX/IECEx Ex ia - Methane 0-10% | 0In Stock | Integrated Infrared (INIR) | CH4 | 0 % | 5 % | UART and Analog | INIR5 Series | |||||||
Mfr: USEQGCDACH4100 TTI: Not Assigned KEMET Availability: Not Available OnlineAir Quality Sensors Dual 2.6x2.6mm CH4 IR Gas 8V | Not Available Online | Gas Sensor | CH4, Flammable Gas | - 40 C | + 85 C | QGC | ||||||||
Mfr: USEQGCDAN8L100 TTI: Not Assigned KEMET Availability: Not Available OnlineAir Quality Sensors Dual 2.6x2.6mm NO IR Gas 8V | Not Available Online | Gas Sensor | Nitric Oxide (NO) | - 40 C | + 85 C | QGC | ||||||||
Mfr: T8100-HD-GN TTI: Not Assigned Amphenol Advanced Sensors Availability: 0In StockAir Quality Sensors | 0In Stock | Gas Sensor | ||||||||||||
Mfr: PS1-IAQ-10-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Indoor Air Quality | 0 PPM | 10 PPM | 5 % | UART | - 40 C | + 55 C | PS1 -Modules | ||||
0In Stock | Solid Polymer | Cl2 | 0 PPM | 5 PPM | Analog | - 20 C | + 40 C | PS1 Series | ||||||
Mfr: USEQGSEH950180 TTI: Not Assigned KEMET Availability: Not Available OnlineAir Quality Sensors Gas Detector Sensor Digital SMD | Not Available Online | Gas Sensor | Alcohol (C2H5OH) | 1.75 V | 3.6 V | - 40 C | + 85 C | QGS | ||||||
Mfr: T8300-DB-BAC TTI: Not Assigned Amphenol Advanced Sensors Availability: Not Available OnlineAir Quality Sensors Duct air kit DD BACnet MS/TP Output | Not Available Online | Gas Sensor | Carbon Dioxide (CO2) | 18 V | 42 V | 0 C | + 50 C | T8300 | ||||||
Mfr: T8100-E-BAC TTI: Not Assigned Amphenol Advanced Sensors Availability: Not Available OnlineAir Quality Sensors Wallmount CO2 Sensor w/ BACnet MS/TP O&DD | Not Available Online | Gas Sensor | Carbon Dioxide (CO2) | 18 V | 42 V | 0 C | + 50 C | T8100 | ||||||
Mfr: T8100-E-HD-BAC TTI: Not Assigned Amphenol Advanced Sensors Availability: Not Available OnlineAir Quality Sensors WallMnt CO2 H&T Sens w/BACnet MS/TP OP&DD | Not Available Online | Gas Sensor | Carbon Dioxide (CO2) | 18 V | 42 V | 0 C | + 50 C | T8100 | ||||||
Mfr: T8100-E-GN TTI: Not Assigned Amphenol Advanced Sensors Availability: Not Available OnlineAir Quality Sensors WallMnt H&T Transmit | Not Available Online | Gas Sensor | Carbon Dioxide (CO2) | 18 V | 42 V | 0 C | + 50 C | T8100 | ||||||
Mfr: T8200-E-H-BAC TTI: Not Assigned Amphenol Advanced Sensors Availability: Not Available OnlineAir Quality Sensors WMCO2 H&T Sen24/7 VA BACnet MS/TP output | Not Available Online | Gas Sensor | Carbon Dioxide (CO2) | 18 V | 42 V | 0 C | + 50 C | T8200 | ||||||
Mfr: T3032-2-20K-24-P TTI: Not Assigned Amphenol Advanced Sensors Availability: 0In StockAir Quality Sensors Industrial CO2 Sens 0-20,000 PPM | 0In Stock | Gas Sensor | Carbon Dioxide (CO2) | 18 VAC, 18 VDC | 30 VAC, 42 VDC | - 30 C | + 50 C | T3000 | ||||||
0In Stock | Catalytic | Flammable | Analog | 2.1 V | - 40 C | + 70 C | VQ Series | |||||||
0In Stock | Infrared - Analog | Hydrocarbon | 0 % | 100 % | Analog | 3 V | 5 V | - 20 C | + 55 C | IR1x Series | ||||
0In Stock | Solid Polymer | O3 | 0 PPM | 5 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | PSD4 Series | |||
Mfr: PSD4-PH3-20 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series Phosphine Digital Solid Polymer Sensor 20ppm | 0In Stock | Solid Polymer | PH3 | 0 PPM | 20 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | PSD4 Series | ||
Mfr: PSD4-TVOC-1000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series TVOC Digital Solid Polymer Sensor 1000ppm | 0In Stock | Solid Polymer | TVOC | 0 PPM | 1000 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | PSD4 Series | ||
0In Stock | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T8031 | |||||||||
Mfr: T5100-GN-LED TTI: Not Assigned Amphenol Advanced Sensors Availability: Not Available OnlineAir Quality Sensors Wallmount CO2 Sensor | Not Available Online | Gas Sensor | Carbon Dioxide (CO2) | 18 V | 42 V | 0 C | + 50 C | T5100 |