Air Quality Sensors
1,214 ResultsPart | Availability | Purchasing | RoHS/Lead | Manufacturer | Type | Sensor Type | Measuring Range - Min | Measuring Range - Max | Accuracy | Output Type | Supply Voltage - Min | Supply Voltage - Max | Minimum Operating Temperature | Maximum Operating Temperature | Series |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr: PS-SMART-NO2-5 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Solid Polymer SMART Nitrogen Dioxide gas sensor probe - 4-20mA and Modbus RTU RS485 - 5ppm | 0In Stock | Amphenol | Solid Polymer | NO2 | 0 PPM | 5 PPM | 5 % | Current | - 40 C | + 85 C | PS-Smart Series | ||||
Mfr: PS-SMART-PH3-2000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Solid Polymer SMART Phosphine gas sensor probe - 4-20mA and Modbus RTU RS485 - 2000ppm | 0In Stock | Amphenol | Solid Polymer | PH3 | 0 PPM | 2000 PPM | 5 % | Current | - 40 C | + 85 C | PS-Smart Series | ||||
Mfr: PS-SMART-PH3-5 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Solid Polymer SMART Phosphine gas sensor probe - 4-20mA and Modbus RTU RS485 - 5ppm | 0In Stock | Amphenol | Solid Polymer | PH3 | 0 PPM | 5 PPM | 5 % | Current | - 40 C | + 85 C | PS-Smart Series | ||||
Mfr: SGX-4CO-HO TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 4 series Electrochemical Carbon Monoxide sensor with High Output 100ppm | 0In Stock | Amphenol | Electro-Chemical | CO | 0 PPM | 100 PPM | Analog | Electro-Chemical | |||||||
Mfr: SGX-7CO-AQ-20 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 7 Series PPB Carbon Monoxide Air Quality Sensor 20ppm | 0In Stock | Amphenol | Electro-Chemical | CO | 0 PPM | 20 PPM | Analog | Electro-Chemical | |||||||
0In Stock | Amphenol | Electrochemical 4-series | Hydrogen | 0 PPM | 1000 PPM | Analog | Electro-Chemical | ||||||||
0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T6613 | |||||||||
0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T6613 | |||||||||
Mfr: T6615-10KF TTI: Not Assigned Amphenol Advanced Sensors Availability: 0In StockAir Quality Sensors Dual Channel CO2 Mod 0-10000 PPM | 0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T6615 | ||||||||
Mfr: PSD4-UART-USB TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4-UART USB with 1m cable | 0In Stock | Amphenol | Solid Polymer | PSD4 Series | |||||||||||
Mfr: SGX-H2-50K-LP TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Low Profile Electrochemical Hydrogen sensor 50,000 ppm | 0In Stock | Amphenol | Electro-Chemical | H2 | 50000 PPM | - 30 C | + 50 C | Electro-Chemical | |||||||
0In Stock | Amphenol | Automotive Air Quality Sensor | Carbon Monoxide + Nitrogen Dioxide + Ammonia | LIN | - 40 C | + 85 C | BLD | ||||||||
Mfr: PS1-O2-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Module Oxygen 25% - UART | 0In Stock | Amphenol | Solid Polymer Module 1-series | 0 % | 25 % | 5 % | UART | 0 C | + 40 C | PS1 -Modules | |||||
Mfr: PS4-SO2-50 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Sulfur Dioxide 50ppm | 0In Stock | Amphenol | Solid Polymer 4-series | Sulfur Dioxide | 0 PPM | 50 PPM | Analog | - 40 C | + 55 C | PS4 Series | |||||
0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T6615 | |||||||||
0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T8200 | |||||||||
Not Available Online | Murata | Ionizer | MHM | ||||||||||||
Mfr: MHM502-01A TTI: Not Assigned Murata Electronics Availability: Not Available OnlineAir Quality Sensors | Not Available Online | Murata | Oxygen Sensor | Oxygen (O) | 11 V | 13.2 V | - 10 C | + 50 C | MHM | ||||||
0In Stock | Amphenol | Electrochemical Low_profile series | Ammonia | 0 PPM | 500 PPM | Analog | - 30 C | + 50 C | Electro-Chemical | ||||||
0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T6613 | |||||||||
0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 0 C | + 50 C | T8042 | |||||||||
0In Stock | Amphenol | Gas Sensor | Carbon Dioxide (CO2) | 18 V | 42 V | 0 C | + 50 C | T8100 | |||||||
Mfr: SGX-CL2-50-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Amphenol | Gas Sensor | Chlorine (Cl2) | 4 | ||||||||||
Mfr: PS1-VOC-10-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Amphenol | Solid Polymer Module 1-series | 0 PPM | 10 PPM | 5 % | UART | - 40 C | + 55 C | PS1 -Modules | |||||
Mfr: PS4-CO-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Carbon Monoxide 100ppm | 0In Stock | Amphenol | Solid Polymer 4-series | Carbon Monoxide | 0 PPM | 100 PPM | Analog | - 40 C | + 55 C | PS4 Series |